For support call us at
+442037470227

Tripp Lite PDUMNH30HVAT Power Distribution Unit (PDU) Battery And Power Supply

Product Name: 5.8kW Single-Phase ATS/Monitored PDU, 208/240V, L6-30R Outlet, 2 L6-30P Inputs, 1U

Brand:Tripp Lite

Part Number (MPN): PDUMNH30HVAT

GTIN (EAN/UPC): 0037332184917

Categories: Power Distribution Units (PDUs)

CPIN:3839460

£1,140.8
Per unit, single order
Ordering multiple units? Get a custom quote.

Reviews

0.0

0

Reviews

5 Star
4 Star
3 Star
2 Star
1 Star

Loading...

Description

Product Features:

  • Monitored 1U Black
  • LCD
  • 1 AC outlet(s) NEMA L6-30P
  • 5800 W

Warranty: 2-year limited warranty

Tripp Lite 5.8kW Single-Phase ATS/Monitored PDU, 208/240V, L6-30R Outlet, 2 L6-30P Inputs, 1U

5.8kW Single-Phase ATS/Monitored PDU, 208/240V, L6-30R Outlet, 2 L6-30P Inputs, 1U

The PDUMNH30HVAT 5.8kW Single-Phase 208/240V ATS/Monitored PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and features one L6-30R outlet—perfect for connecting a single device or a 0U 208/240V PDU with an L6-30P plug. Dual 3.05 m (10-ft.) input cords with L6-30P plugs connect to separate primary and secondary single-phase power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption. Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP. Provides real-time load/current data with billing-grade accuracy (+/- 1 percent). Tiered access privileges allow both an administrator and a guest to log in. Automated alerts help prevent accidental overloads, power loss and downtime. Digital display indicates power availability, voltage, source A/B input status, output load and power factor, as well as temperature and humidity conditions with the optional ENVIROSENSE module (sold separately).

- Two single-phase L6-30P inputs with 3.05 m (10-ft.) cords
- L6-30R outlet for connecting single device or 0U vertical PDU
- Automatic transfer switching within 1–5 ms
- Ethernet network interface for remote access
- Digital LED display for real-time status monitoring

- Provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations
- Dual 3.05 m (10-ft.) input cords with L6-30P plugs connect to separate primary and secondary single-phase power sources
- Connects a single device or indirectly powers equipment through a 0U 208/240V PDU with L6-30P input (sold separately)
- Dynamic solid-state (TRIAC) automatic transfer switching
- Switches to secondary power source if primary source fails or becomes unstable
- 1–5 ms transfer time ensures uninterrupted operation of connected equipment
- Built-in processor monitors both sources and prevents switching if secondary source is unavailable or of lower quality than primary source
- Reports source A and source B input power status and other information, including power availability, line voltage, frequency, amps, kilowatts and power factor
- Built-in Ethernet network interface allows full remote access for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP
- Real-time load/current data with billing-grade accuracy (+/- 1 percent)
- Tiered access privileges allow both an administrator and a guest to log in
- Automated alerts help prevent accidental overloads, power loss and downtime
- Optional ENVIROSENSE module (sold separately) monitors temperature and humidity
- 10/100 Mbps auto-sensing allows optimal communication with 10/100 Base-T networks
- Supports HTTP, HTTPS, PowerAlert®, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP and NTP
- Compatible with EIA-standard 19 in. 4-post racks and rack enclosures
- Optional PDU4PKIT rail kit adds rear rack-mounting support

Tripp Lite 5.8kW Single-Phase ATS/Monitored PDU, 208/240V, L6-30R Outlet, 2 L6-30P Inputs, 1U, Monitored, 1U, Horizontal, Metal, Black, LCD

Tripp Lite 5.8kW Single-Phase ATS/Monitored PDU, 208/240V, L6-30R Outlet, 2 L6-30P Inputs, 1U. PDU types: Monitored, Rack capacity: 1U, Mounting: Horizontal. AC outlets quantity: 1 AC outlet(s), AC outlet types: NEMA L6-30P, Power plug: NEMA L6-30P. Cable length: 3 m, Certification: Tested to UL/CSA 60950-1 (USA, Canada), FCC Class A (Emissions), NOM (Mexico). Nominal input voltage: 200-240 V, Maximum current: 30 A, AC input frequency: 50 - 60 Hz. Width: 430 mm, Depth: 355.6 mm, Dimensions (WxDxH): 430 x 356 x 44 mm

Specification

Design

PDU types
Monitored
Rack capacity
1U
Mounting
Horizontal
Housing material
Metal
Product colour
Black
Display
LCD
On/off switch
Yes

Ports & interfaces

AC outlets quantity
1 AC outlet(s)
Power plug
NEMA L6-30P
AC outlet types
NEMA L6-30P
Ethernet LAN (RJ-45) ports
1

Features

LED indicators
Yes
Cable length
3 m
Certification
Tested to UL/CSA 60950-1 (USA, Canada), FCC Class A (Emissions), NOM (Mexico)

Power

Nominal input voltage
200-240 V
AC input frequency
50 - 60 Hz
Maximum current
30 A
Nominal output voltage
200-240 V
Maximum power
5800 W

Weight & dimensions

Width
430 mm
Depth
355.6 mm
Dimensions (WxDxH)
430 x 356 x 44 mm
Height
43.7 mm
Weight
6.97 kg

Packaging data

Package dimensions (WxDxH)
550 x 525 x 190 mm
Package weight
8.41 kg
Package width
549.9 mm
Package depth
525 mm
Package height
190 mm

Operational conditions

Operating temperature (T-T)
0 - 50 °C
Storage temperature (T-T)
-15 - 60 °C
Operating relative humidity (H-H)
5 - 95%
Operating altitude
0 - 3000 m
Operating temperature (T-T)
32 - 122 °F

Technical details

Sustainability certificates
RoHS

Logistics data

Country of origin
China
Products per master (outer) case
1 pc(s)

Media