For support call us at
+442037470227

Tripp Lite PDU3EVSR10L2130 Power Distribution Unit (PDU) Battery And Power Supply

Product Name: 10kW 3-Phase Switched PDU, LX Interface, 200/208/240V Outlets (24 C13/6 C19), LCD, NEMA L2130P, 3m/10 ft. Cord, 0U 1.8m/70 in. Height, TAA

Brand:Tripp Lite

Part Number (MPN): PDU3EVSR10L2130

GTIN (EAN/UPC): 0037332209474

Categories: Power Distribution Units (PDUs)

CPIN:4726476

£2,625.6
Per unit, single order
Ordering multiple units? Get a custom quote.

Reviews

0.0

0

Reviews

5 Star
4 Star
3 Star
2 Star
1 Star

Loading...

Description

Product Features:

  • Three-phase Switched 0U Black
  • LCD
  • 30 AC outlet(s) C13 coupler, C19 coupler
  • 10000 W

Tripp Lite 10kW 3-Phase Switched PDU, LX Interface, 200/208/240V Outlets (24 C13/6 C19), LCD, NEMA L2130P, 3m/10 ft. Cord, 0U 1.8m/70 in. Height, TAA

10kW 3-Phase Switched PDU, LX Interface, 200/208/240V Outlets (24 C13/6 C19), LCD, NEMA L2130P, 3m/10 ft. Cord, 0U 1.8m/70 in. Height, TAA

The PDU3EVSR10L2130 10kW 3-Phase Switched Power Distribution Unit provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. By reducing the frequency of on-site visits, these advanced remote capabilities can save you money and reduce downtime.

The 0U PDU features 30 switched outlets (24 C13 and 6 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A 10-foot cord with NEMA L21-30P plug connects the PDU to a compatible AC power source, generator or protected UPS.

The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.

A color touchscreen LCD lets you toggle between menus to monitor input current level per phase, output current per load bank and per outlet with ±1% billing-grade accuracy, environmental sensor data and network information. It also generates a unique QR code to allow access to the switchable PDU through a mobile device.

Distributes, Monitors and Manages Network-Grade AC Power
- 10kW 200/208/240V switched PDU with 3-phase input
- Recommended for network applications requiring individual outlet control, load shedding and remote monitoring of critical network components
- NEMA L21-30P plug with 10 ft. cord connects to compatible AC power source
- Firmware upgrades support future product enhancements

30 Switched Outlets Distribute AC Power
- 24 C13 and 6 C19 outlets split into 3 separately breakered load banks
- Individual outlets can be remotely controlled to power up, power down, reboot or lock out devices
- Plug-lock insert sleeves prevent cables from becoming accidentally disconnected

Color Touchscreen LCD
- Reports network data, including IP address, input current level per phase, and output current per load bank and per outlet with ±1% billing-grade accuracy
- Generates unique QR code for read-only access to PowerAlert® Device Manager via mobile device
- Full access available by logging into PowerAlert Device Manager via browser as user with read/write credentials

Built-In LX Platform Interface
- Allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH
- Supports 10/100 Mbps auto-sensing for communication with an Ethernet network
- Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities
- No Java required

Broad Communications Compatibility
- Supports IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP
- Supports automatic and manual assignment of IP address

Easy 0U Installation in EIA-Standard 19 in. Racks
- Mounts vertically using included toolless buttons or rack-mounting brackets
- Included PDUMVROTATEBRKT allows mounting with rear-facing outlets

TAA-Compliant
- Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases

Tripp Lite 10kW 3-Phase Switched PDU, LX Interface, 200/208/240V Outlets (24 C13/6 C19), LCD, NEMA L2130P, 3m/10 ft. Cord, 0U 1.8m/70 in. Height, TAA, Switched, 0U, Three-phase, Vertical, Metal, Black

Tripp Lite 10kW 3-Phase Switched PDU, LX Interface, 200/208/240V Outlets (24 C13/6 C19), LCD, NEMA L2130P, 3m/10 ft. Cord, 0U 1.8m/70 in. Height, TAA. PDU types: Switched, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 30 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: NEMA L21-30P. Cable length: 1.83 m, Certification: Tested to UL60950-1: 2007 R10.14 (USA), CAN/CSA-C22.2 NO. 60650-1-07+A1: 2011+A2: 2014 (Canada).... Monitoring: Current, Humidity, Power, Temperature, Outlet control: Lock-out, Recycle, Turn off, Turn on, Supported network protocols: IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP. Nominal input voltage: 200-240 V, Maximum current: 24 A, AC input frequency: 50 - 60 Hz

Specification

Design

PDU types
Switched
Type
Three-phase
Rack capacity
0U
Mounting
Vertical
Housing material
Metal
Product colour
Black
Display
LCD
On/off switch
Yes

Ports & interfaces

AC outlets quantity
30 AC outlet(s)
Power plug
NEMA L21-30P
AC outlet types
C13 coupler, C19 coupler
Master AC outlets quantity
24
Slave AC outlets quantity
6

Features

LED indicators
Yes
Cable length
1.83 m
Certification
Tested to UL60950-1: 2007 R10.14 (USA), CAN/CSA-C22.2 NO. 60650-1-07+A1: 2011+A2: 2014 (Canada) Class A Part 15 (Emissions) NOM (Mexico) TAA Compliant

Management features

Monitoring
Current, Humidity, Power, Temperature
Outlet control
Lock-out, Recycle, Turn off, Turn on
Supported network protocols
IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP

Power

Nominal input voltage
200-240 V
AC input frequency
50 - 60 Hz
Maximum current
24 A
Nominal output voltage
200-240 V
Power protection features
Short circuit
Maximum power
10000 W

Weight & dimensions

Width
55.1 mm
Depth
72.6 mm
Dimensions (WxDxH)
55 x 73 x 1778 mm
Height
1778 mm
Weight
9.08 kg

Packaging data

Package dimensions (WxDxH)
175 x 245.1 x 1927.1 mm
Package weight
12.3 kg
Package width
245.1 mm
Package depth
1927.1 mm
Package height
175 mm

Packaging content

Manual
Yes

Operational conditions

Operating temperature (T-T)
0 - 50 °C
Storage temperature (T-T)
-15 - 60 °C
Operating relative humidity (H-H)
5 - 95%
Operating altitude
0 - 3000 m
Operating temperature (T-T)
32 - 122 °F

Technical details

Sustainability certificates
RoHS

Logistics data

Country of origin
Taiwan
Products per master (outer) case
1 pc(s)

Media